Touch Record + Touch Hold:
5.7.5

Held Controls

Held Controls Buffer:
Clearing Held Controls:
Date printed: 27.08.03
With both TOUCH RECORD and TOUCH HOLD engaged, Touch events per-
form the following functions when dynamic controls are in the Control
Modes indicated (remember Un-touch events are suppressed):
• READ: Touch will change to and stay in AUDITION.
• WRITE ENABLE: Touch will change the control from WRITE
ENABLE to WRITE RECORD and stay in WRITE RECORD when
released.
• TRIM ENABLE: Touch will change the control from TRIM ENABLE
to TRIM RECORD and stay in TRIM RECORD when released.
• ISOLATE: Touch/Un-touch events of Isolated controls are not recog-
nized by AutoTouch+.
<Option>
• With <Read Safe> checked on the Misc Options page (see
5.21.8), AUDITION mode is defeated for controls in READ, and only
written values will be heard.
• The Master Panel TOUCH RECORD and TOUCH HOLD keys may be over-
ridden by checking options on the <Master Panel Overrides> section of
the Master Panel Options page (see
ers can have TOUCH RECORD and TOUCH HOLD set to <ON>, <OFF>,
or to follow the Master Panel <Follows Panel>. TOUCH RECORD and
TOUCH HOLD for Switches can also have <ON> and <OFF> overrides
or be set to follow the Master Panel <Follows Panel>
• The Un-touch function of either TOUCH RECORD or TOUCH HOLD may
be changed by using the AUTO MODE modifier key. For details, refer to
chapter
A control that is touched with TOUCH HOLD engaged becomes a "held"
control. Held controls are also known as "Held Objects." Controls that are
held not only stay in their Touched mode when released, they are identi-
fied by the system as being held.
As controls are placed into a held status, they are added to a list of controls
stored in the "Held Controls Buffer." The CLR HELD key in the HELD
section of the AutoTouch+ Panel will light if one or more control is held.
The Held Controls list is used as a filter for the HELD pre-selectors in the
Control Modes and Global Record sections of the Automation Master
Panel.
Clear Held Controls Buffer: Pressing the CLR HELD key will take all Held
controls out of Hold. It will also clear the list of controls in the Held Con-
trols Buffer.
Clear Held Controls Modes: Controls may be taken out of hold in the
following ways:
• When TOUCH HOLD is turned OFF <Option>
• Upon Punch-Out <Option>
• At the end of a Mix Pass <Option>
<Option>
• With <When Touch Hold Turned Off> checked in the <Clear Held
Objects> section of the Hold Options page (also refer to
5.21.7), all held controls are cleared when TOUCH HOLD is turned Off.
• With <Upon Punch-Out> checked in the <Clear Held Objects> section
of the Hold Options page, any Held control is cleared upon punch-out.