3.3.7

EQ Section

INPUT
DIR OUT
IN 1
ON
Input
Out
IN 2
Busses
GEN
Meters
1
2
ON
ON
AUX
MONO
3
4
ON
ON
1
2
ON
ON
AUX
STEREO
3
4
ON
ON
PROCESSING
EQ
FILT
CMP/
EXP/
DYN
LIM
GTE
INS
DLY
OPT
3.3.7.1

Assigning the EQ Section

OUT/
INPUT
N-1
EQ
FILTER
EQ2
LIM/
EXP/
COMP
GATE
INSERT
DELAY
MONO
ADD.
AUX
AUX
STEREO
PAN
AUX
PAGE
PAGE
1
2
PAGE
PAGE
3
4
AUTO
SHOW
ASSIGN
VALUES
MODES
FREEZE
LINK
OFF
ACCESS
MENU
Date printed: 03.09.03
From the Channel Strip, the complete four-band EQ Section can be
switched ON/OFF using the channel strip EQ key.
EQ assignment is available for all channel types.
EQ1 Mode
For each of the four bands (LF, LM, HM, and HF), one of the four pages is
used. Each PAGE will contain the band ON/OFF switch, constant-
Q/constant-range selection (or shelving/bell for the highest and lowest
bands), frequency setting, and gain controls for one of the four bands.
EQ2 Mode
Each page will contain the same EQ parameter for all four bands. For ex-
ample, PAGE 4 will contain the gain controls for all four bands.
EQ2 mode can only be selected from the Master Menu Selector.
Notes:
In addition to a Master ON/OFF function, each of the four single bands
can be switched ON/OFF individually. As a consequence, the EQ key on
the Channel Strip has no effect if all EQ bands have been switched OFF
individually.
Assigning the EQ to the LACP using the ASN SEL or MMS keys will not
activate the EQ. If it is not already engaged, the EQ key must be pressed to
activate the unit, and the EQ key will illuminate.
If the EQ is not engaged, the EQ curve will not be displayed on the
Graphic Controller (although the EQ screen will appear when rotary en-
coders assigned to EQ are touched or moved).
A.
Global Assignment:
• Press EQ on the Master Menu Selector.
The displays of all Channel Strips will switch over and indicate the EQ
control parameters in EQ1 mode, except those in FREEZE mode; see
chapter
• To switch over to EQ2 mode, press EQ on the Master Menu Selector a
second time.
• Press one of the PAGE 1 through 4 keys on MMS to select the desired
set of parameters (depending upon selected EQ1 or EQ2 mode).
For EQ1 mode, page assignment is as follows:
PAGE 1 = EQHI (high frequency band)
PAGE 2 = EQHM (high-mid frequency band)
PAGE 3 = EQLM (low-mid frequency band)
PAGE 4 = EQLO (low frequency band)
• Press one of the PAGE 1 through 4 keys on MMS to select the desired
band.
For EQ2 mode, page assignment is as follows:
PAGE 1 = Display of the last used frequency
PAGE 2 = Center/turnover frequency controls
PAGE 3 = Q controls (shelving/bell for H/L, and constant
PAGE 4 = Gain controls (boost/cut)
• Press one of the PAGE 1 through 4 keys on the Master Menu Selector
(MMS) to select the desired set of parameters.
Note:
EQ2 mode can only be selected from the Master Menu Selector (MMS).
SW V3.3
3.3.2.
Q/constant range for HM/LM)
D950 Digital Mixing System
Desk Operation 3-35