Delay Section; Assigning The Delay Section - Studer D950 Operating Instructions Manual

Sw v 3.3
Table of Contents

Advertisement

D950 Digital Mixing System
3.3.12

Delay Section

INPUT
DIR OUT
IN 1
ON
Input
Out
IN 2
Busses
GEN
Meters
1
2
ON
ON
AUX
MONO
3
4
ON
ON
1
2
ON
ON
AUX
STEREO
3
4
ON
ON
PROCESSING
EQ
FILT
CMP/
EXP/
DYN
LIM
GTE
INS
DLY
3.3.12.1

Assigning the Delay Section

OUT/
INPUT
N-1
EQ
FILTER
EQ2
LIM/
EXP/
COMP
GATE
INSERT
DELAY
MONO
ADD.
AUX
AUX
STEREO
PAN
AUX
PAGE
PAGE
1
2
PAGE
PAGE
3
4
AUTO
SHOW
ASSIGN
VALUES
MODES
FREEZE
LINK
OFF
ACCESS
MENU
3-70 Desk Operation
A delay function is available for all Channel Types, that can be switched
ON/OFF on the Channel Strip using the DLY key.
The Delay Section provides selection and control of the delay function
(ON/OFF) and setting of delay time. Delay time can be adjusted from 0
through 47 samples, and from 1 ms through 100 ms (or, depending on the
system configuration, up to 240 ms). Delay time in ms is automatically
converted into a delay distance (from 0 through 33.3 cm, and from 0.34
through 34/81.5 m, depending on the system configuration). Both values
are displayed simultaneously.
A.
Global Assignment:
• Press DELAY on the Master Menu Selector.
The displays of all Channel Strips will switch over and indicate the
delay control parameters, except those in FREEZE mode; see
3.3.2.
• PAGE 1 is the only page available.
B.
Local Assignment on the Channel Strip:
• Press ASN SEL; the ASN SEL key will flash.
• Press the DLY key. The insert parameters will be displayed on the
LACP (= PAGE 1 only)
C.
Local Assignment affecting all Channel Strips:
• Press LINK ACCESS on the Master Menu Selector.
• Pressing a local assignment key will now affect all Channel Strips. The
same functions as described in "B" are available.
D.
Local Assignment with Auto Assign Modes "In-Only":
• Press AUTO ASSIGN MODES on the Master Menu Selector once
(AUTO ASSIGN MODES is illuminated).
• Pressing the DLY key on the channel strip will assign the DELAY pa-
rameters to the LACP without pressing the ASN SEL key, provided
the function toggles to an IN (or ON) status. If it toggles to an OUT (or
OFF) status, the knob status does not change.
E.
Local Assignment with Auto Assign Modes "In and Out":
• Press AUTO ASSIGN MODES on the Master Menu Selector twice
(the AUTO ASSIGN MODES key and the ASN SEL keys on all the
channel strips are illuminated).
• Every time the DLY key on the channel strip is pressed (regardless of
what status it toggles to), the DELAY parameters are assigned to the
knobs on the LACP).
Notes:
AUTO ASSIGN MODES and LINK ACCESS may be engaged at the same
time.
SW V3.3
chapter
Date printed: 03.09.03

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents