Studer D950 Operating Instructions Manual page 347

Sw v 3.3
Table of Contents

Advertisement

D950/Vista7 Digital Mixing System
point, rather than started there. Also, specific Glide transitions may be
suppressed while others are allowed.
Scene Capture:
Any specific set of controls, their settings, and automation modes can be
saved in the Scene buffer. This allows the exact settings of those controls
to be punched into the mix at a later time when the scene occurs again.
Read Lock:
This forces the automation system to playback the current Active Mix and
ignore any and all key and control changes. This ensures a perfect audition
playback or layback to the final master record machine.
Real Time Switch Editing:
Switch data may be edited in real time allowing the movement of the in-
point and or the out-point, as well as adding or deleting Mutes and Ins or
Outs.
Event List Editor:
All automation events may be edited (moved, copied, or deleted) offline
using the Event List Editor.
Full Offline Editing:
The D950 OFLA application is integrated in AutoTouch+. Mix data com-
prising the entire mix, or any specified objects for any specified time range
may be changed, merged, or copied with other mixes or itself.
Protection:
Any set of controls may be placed in a protected status. Protected controls
playback their recorded moves, but are prevented from being enabled for
Write or Trim operations. This is useful for protecting channels or controls
that have already been written, while working on other aspects of the mix.
Write Zone:
A Write Zone may be specified so that no data can be written outside the
time range specified. This is useful for working on a specific scene or sec-
tion while protecting the rest of the mix from accidentally writing into it.
This will also facilitate the automatic punch-out (with or without glide) at
the end of the Write Zone.
Auto-Punch:
When Auto-Punch is active the system will automatically punch Write
Enabled controls into RECORD at the beginning of the Write Zone.
Stop Frame Automation:
The Stop Frame automation feature makes it possible to write specific
control values between timecode locations. The user can stop timecode
playback at a specific location, set any number of controls to desired val-
ues, and move to the next location forward in time where values may again
be adjusted. The initially set values will be recorded between the timecode
locations.
New Automation Master Panel:
A new Automation Master Panel is required to run AutoTouch+. It will
replace the existing Master Panel in both Classic and M2 versions of the
D950 work surface. (V3.0 software will run on the D950 without the new
panel, but the automation system will be inoperative.)