Studer D950 Operating Instructions Manual page 136

Sw v 3.3
Table of Contents

Advertisement

D950 Digital Mixing System
PAGE 2 (EXP)
ATTACK TIME:
RELEASE TIME:
THRESHOLD:
3-60 Desk Operation
RATIO:
The expander ratio (RTIO) can be adjusted from 1:1 (no expansion) to
1:20 (heavy expansion) in the following discrete steps: 1:1, 5:4, 4:3, 3:2,
5:3, 2:1, 3:1, 5:1, 7:1, 10:1, 20:1. The SW key functions as the expander
ON/OFF key.
The expander attack time (ATCK) can be adjusted within a 200 µs to 1 ms
range, in 9 discrete steps (0.2 ms, 0.3 ms, 0.4 ms, 0.5 ms, 0.6 ms, 0.7 ms,
0.8 ms, 0.9 ms, 1 ms).
The expander release time (RLSE) can be adjusted within a 10 ms through
10 s range, in discrete steps (10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms,
300 ms, 500 ms, 1 s, 2 s, 3 s, 5 s, 10 s).
The expander threshold level (THRS) can be adjusted in 1 dB steps from
0 dB
to –96 dB
FS
Output level
[dBFS]
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
1
–90
–90
–80
Curve
1
1
1
2
3
4
5
6
7
SW V3.3
.
FS
2
3 4
5
6
–70
–60
–50
–40
Expander
Threshold [dB]
OFF
ON
ON
ON
ON
ON
ON
ON
ON
7
–30
–20
–10
Slope
any
any
–96
any
–30
1:1
–60
2:1
–60
5:1
–60
20:1
–30
2:1
–30
5:1
–30
20:1
Date printed: 03.09.03
Input level
[dBFS]
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents