Limiter/Compressor Parameters On The Lacp - Studer D950 Operating Instructions Manual

Sw v 3.3
Table of Contents

Advertisement

D950 Digital Mixing System
3.3.9.3

Limiter/Compressor Parameters on the LACP

Example 1 (PAGE 1, LIM):
Dynamics control parameter (Limiter/Compressor)
LIMITER ON/OFF
ATTACK TIME
RELEASE TIME/HOLD
THRESHOLD
3-52 Desk Operation
1
SW
ON
AUTO
2
SW
ATCK
AUTO
3
SW
RLSE
AUTO
4
SW
THRS
AUTO
LIM
n–1
1
2
TALK
3
4
LAST MODE
PAGE
FREEZE
SW V3.3
Available operating elements and their function
SW key
=
Limiter ON/OFF
Rotary encoder
=
no function
LED bar
=
no function
Center LED
=
no function
Display
=
ON/OFF
SW key
=
no function
Rotary encoder
=
Attack time adjustment; 0.2 to 1 ms
LED bar
=
Dot display, indicates adjusted attack time
Center LED
=
no function
Display
=
ATCK; label of control parameter
0.5; attack time set to 0.5 ms
SW key
=
HOLD function ON/OFF; ON = 150 ms / OFF = 0 ms
Rotary encoder
=
Release time adjustment; 10 ms to 10 s
LED bar
=
Dot display, indicates adjusted release time
Center LED
=
no function
Display
=
RLSE; label of control parameter
100m; release time set to 100 ms
1s; release time set to 1 s
SW key
=
no function
Rotary encoder
=
Threshold adjustment; 0 to –48 dBFS in 1 dB steps
LED bar
=
Bar display, indicates threshold
Full bar = 0, empty bar = –48 dB
Center LED
=
Is ON if threshold is set to 0 dBFS
Display
=
THRS; label of control parameter
– 24; indicates threshold value –24 dBFS
Indication of Limiter/Compressor selection
Display
=
LIM; limiter parameters (page 1)
COMP; compressor parameters (page 2)
CLVL; level/gain parameters (page 3)
KEY; common parameters for limiter and
compressor (page 4)
Date printed: 03.09.03

Hide quick links:

Advertisement

Table of Contents
loading