D950/Vista7 Digital Mixing System
Switch & Encoder Control Modes: A set of Control Mode activators are provided exclusively for the CAS
Switch & Encoder Controls:
5-172 AutoTouch+
switches and encoders. The CAS switches and encoders Control Mode
may be selected by pressing the switches and encoders Control Mode key
for the desired mode. Modes may also be selected globally or locally (via
the channel strip for assigned channel).
CAS switches and encoders Control Mode Activators:
• READ: READ
• ISO: ISOLATE
• ABS: WRITE ENABLE (ABS is a legacy of AutoTouch 2.5)
• TRIM: TRIM ENABLE
The CAS has five keys that support switch and encoder automation. These
keys allow a precise set of controls to be easily chosen for automation.
They also allow separate control over switches and encoders.
• ONE: Allows the creation of a temporary list of controls to be auto-
mated. Holding down the ONE key and touching the desired controls
will select those controls for automation. Touching an encoder will se-
lect both the encoder and its associated switches. The list is deleted
upon the completion of the automation operation.
• MANY: Allows the creation of a list of controls to be automated that
may be kept for future use. Holding down the MANY key and touching
the desired controls will select those controls for automation. Touching
the encoder will select both the encoder and associated switches. The
MANY key will illuminate indicating that a list of controls has been cre-
ated. Pressing the MANY key recalls the list of controls for further auto-
mation operations.
• SECT SWITCH (section switches): Allows the creation of a temporary
list of switches to be automated. Pressing the SECT SWITCH key and
touching any switch will select (or deselect) the switches for the entire
section from the selection list. The list is deleted upon the completion
of the automation operation.
• SECT ROTARY (section rotaries): Same as the SECT SWITCH mode, ex-
cept for encoders for an entire section.
• ALL: Selects all controls, and then individual control status (in the list
or not) can be toggled on or off as needed.
When an entire section or the ALL function is used, this refers to the visible
Note:
controls on the CAS. So, for example, if the ALL key is used, only the
control from the Compressor or the Limiter will be included, as only one
of those sections can be visible on the CAS at a time. Of course the
alternate controls can be added by touching them and adding them to the
list. This affects AUX Sends and any other "hidden" controls as well.