USER USER
3.3.7.2

EQ Parameters

EQ1 Mode:
EQ BAND ON/OFF:
FREQUENCY:
Date printed: 03.09.03
Example: Local Assignment
• Press ASN SEL on the Channel Strip; the ASN SEL key will flash.
The flashing ASN SEL key indicates Select Assignment Mode.
• Press EQ on the Channel Strip, followed by one of the four PAGE
keys, to control the EQ parameters of the desired band.
AS-1
n–1
1
2
TALK
3
4
LAST MODE
PAGE
FREEZE
The four-band EQ section can be used in one of two distinct modes: EQ1
and EQ 2.
Each band of the EQ Section is available on an individual Page (1 through
4), consisting of three parameters: Q (bandwidth), center frequency
(in Hz), Gain (in dB), as well as ON/OFF selection of the particular band.
The SW key on the LACP controls the ON/OFF function for the selected
band. The band is active when the key is illuminated.
Q:
The Q (bandwidth) can be set to several discrete values. In addition, for
the low- and high-frequency bands, a shelving-type filter can be selected.
• EQHI, high-frequency: SHLV (shelving-type), or Q = 0.27 through
8.7, in 30 steps. The SW key is illuminated when in SHLV mode.
• EQHM, high-/mid-frequency: Q = 0.27 through 8.7, in 30 steps,
• EQLM, low-/mid-frequency: Q = 0.27 through 8.7, in 30 steps,
• EQLO, low-frequency: SHLV (shelving-type), or Q = 0.27 through
8.7, in 30 steps. The SW key is illuminated when in SHLV mode.
Note:
For EQHM and EQLM bands, Q can be selected between "constant-Q"
(ConQ) and "constant-range" (ConR) filter types, whereas for the EQHI
and EQLO bands, "shelving" (SHLV) or "constant-Q" can be selected.
The SW keys are illuminated when the bands are in constant-range or
shelving modes, respectively.
GAIN:
Boost/cut adjustment; ±18 dB in steps of 0.5 dB.
Center frequency (or, if SHLV is selected for the low or high frequency
band: turnover frequency) adjustment. For all four bands, the center or
turnover frequency can be adjusted from 20 Hz through 20 kHz, in 120
steps.
SW V3.3
AS-1
AS-1
n–1
n–1
1
2
TALK
1
2
TALK
3
4
LAST MODE
3
4
LAST MODE
PAGE
PAGE
FREEZE
FREEZE
D950 Digital Mixing System
AS-1
EQHI
n–1
n–1
1
2
TALK
1
2
TALK
3
4
LAST MODE
3
4
LAST MODE
PAGE
PAGE
FREEZE
FREEZE
Desk Operation 3-37
AS-1
n–1
1
2
TALK
3
4
LAST MODE
PAGE
FREEZE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents