; modified sections (JM 13.09.01):
; [CCU_0]
; new downloadfirmware for ccu
; ApplicationFilename=C:\D950SYSTEM\c9503601.pgm
;
; not mandatory if no blocked keys on new AMP required
; [BLOCKED_KEYS]
; NumberOfBlockedAmpKeys=
; BlockedAmpKey0=
; [PHYSICAL_UI]
; NumberOfHDLCMaster=
; NumberOf4ChStrips=
;
;
; NumberOf4ChBargraph=
; NumberOfCcu=
;
;
; NumberOfMpu=
;
;
; NumberOfCas=
;
;
; IsRotaryResolutionLow=
;
; FaderValueWithoutTouch= Allows processing of fader values without preceding fader touch
;
; RotaryValueWithoutTouch= Allows processing of rotary values without preceding rotary touch
;
; ExtendedHdlcErrMessage= Allows Extended HDCL Error messages readout in D950system.log
;
[PHYSICAL_UI]
NumberOfHDLCMaster=1
NumberOf4ChStrips=4
NumberOf4ChBargraph=4
NumberOfCcu=1
NumberOfMpu=1
NumberOfCas=1
IsRotaryResolutionLow=No
FaderValueWithoutTouch=No
RotaryValueWithoutTouch=No
ExtendedHdlcErrMessage=Yes
; [4CH_STRIP_NODE_0]
; MasterAddr=
;
;
;
;
; HDLCAddr=
;
; LACPPresent=
; BargraphPresent=
; NewBargraph=
; BargraphHDLCAddr=
;
; DeskLocation=
; ApplicationFilename= location and name of Application to download (k9404902.pgm for D950 Classic,
;
;
Date printed: 05.12.03
number of blocked keys in new Automation Master Panel (AMP) V3.0
inactive key number 0..51
actual Desk resources
corresponds HDLC Master controllers installed in the Control PC (1..4)
corresponds to 4-channel strips of the whole D950 System
Note:
NumberOf4ChStrips can be smaller than defined below
([4CH_STRIP_NODE_x]), but not greater.
corresponds to 4-channel Bargraph of the whole D950 System
corresponds to Central Control Units of the whole D950 System
Note:
NumberOfCcu can be smaller than defined below
([CCU_x]), but not greater.
corresponds to Multiformat Panning Units of the whole D950 System
Note:
NumberOfMpu can be smaller than defined below
([MPU_x]), but not greater.
corresponds to Central Assign Section Units of the whole D950 System
Note:
NumberOfCas can be smaller than defined below
([CAS_x]), but not greater.
indicates if new Encoders with 40 instead of 100 cycles per Rotation
are assembled in 4-channel strips (Yes/No dft:No)
(Yes/No dft:No)
(Yes/No dft:No)
(Yes/No dft:Yes)
first 4-ch. strip with logical Node No. (starting with 0)
connected to HDLC Master x (0..NumberOfHDLCMaster-1)
HDLC master address 1 = IP module B
HDLC master address 2 = IP module C
HDLC master address 3 = IP module D
corresponds to Strip Node HDLC address
(starting with 0, 4, 8..60 in decimal)
indicates, if LACP (16 Rotaries, displays etc.) is present (Yes/No dft:No)
indicates, if 4-ch. Bargraph is present (Yes/No dft:No)
indicates, if new 2-Sandwich PCB Bargraph is present (Yes/No dft:No)
corresponds to Bargraph Node HDLC address
(same as Strip Node Addr., starting with 0, 4, 8..60 in decimal)
corresponds to the physical location on the Desk (Left/Right
dft:Left)
SW V3.3
HDLC master address 0 = IP module A
k9504902.pgm for D950 M2,
f9504902.pgm for D950 Fader only)