Date printed: 05.08.03
3.
Now you need to select the desired relay (use the arrow button to open a
list of relays), and to determine its mode of operation to either latching
(contact closed when trigger conditions are fulfilled) or impulse (contact
closed for a short time when trigger conditions are fulfilled, and then
opened again). Impulse mode closure time can be set to 100 or 200 ms.
4.
The Triggers have to be set according to the application of the selected
relay. All Triggers always work in a logical AND fashion:
•
The desired Source must be patched into the appropriate Channel
(implicitly understood and done in the Patch), and
There is the possibility to check up to five other Triggers to finally trigger
the relay:
•
User key 1, and
•
User key 2, and
•
Input Selector, and
•
Channel On (MUTE), and
•
Fader open.
Any combination of the five possibilities above can be used. It is also pos-
sible to select from a default list of pre-configured Trigger combinations:
•
Fader start, or
•
User Defined.
SW V3.3
D950/Vista Digital Mixing System
Select a Relay
GC Operation 4-121