D950 Digital Mixing System
[4CH_STRIP_NODE_0]
MasterAddr=1
HDLCAddr=0
LACPPresent=Yes
BargraphPresent=Yes
NewBargraph=Yes
BargraphHDLCAddr=0
DeskLocation=Left
ApplicationFilename=C:\D950SYSTEM\k9504902.pgm
[4CH_STRIP_NODE_1]
MasterAddr=1
HDLCAddr=4
LACPPresent=Yes
BargraphPresent=Yes
NewBargraph=Yes
BargraphHDLCAddr=4
DeskLocation=Left
ApplicationFilename=C:\D950SYSTEM\k9504902.pgm
[4CH_STRIP_NODE_2]
MasterAddr=1
HDLCAddr=8
LACPPresent=Yes
BargraphPresent=Yes
NewBargraph=Yes
BargraphHDLCAddr=8
DeskLocation=Right
ApplicationFilename=C:\D950SYSTEM\k9504902.pgm
[4CH_STRIP_NODE_3]
MasterAddr=1
HDLCAddr=12
LACPPresent=Yes
BargraphPresent=Yes
NewBargraph=Yes
BargraphHDLCAddr=12
DeskLocation=Right
ApplicationFilename=C:\D950SYSTEM\k9504902.pgm
; [CCU_0]
; MasterAddr=
;
;
;
;
; HDLCAddr=
; 2ndBSUPresent=indicates, if 2nd Bank Select Unit is present (Yes/No dft:No)
; 2ndMMSPresent=indicates, if 2nd Master Menu Selector is present (Yes/No dft:No)
; 2ndCFUPresent=indicates, if 2nd Central Facilities Unit is present (Yes/No dft:No)
; ApplicationFilename= location and name of Application to download (c9503601.pgm)
[CCU_0]
MasterAddr=1
HDLCAddr=240
2ndBSUPresent=No
2ndMMSPresent=No
ApplicationFilename=C:\D950SYSTEM\c9503601.pgm
6-30 System Administration
first Central Control Unit with logical Node No. (starting with 0)
connected to HDLC Master x (0..NumberOfHDLCMaster-1)
HDLC master address 1 = IP module B
HDLC master address 2 = IP module C
HDLC master address 3 = IP module D
corresponds to Ccu HDLC address (starting with 240)
SW V3.3
HDLC master address 0 = IP module A
Date printed: 05.12.03