Control Group Filter
Date printed: 03.09.03
When Control Group Editing is activated, the Graphic Controller auto-
matically activates the Control Group Filter dialog box for the selected
Control Group:
In the Control Group Filter dialog, the user can define functions to be
grouped or not. To group the desired function, the appropriate Select
checkbox must be checked. If Select is unchecked, the functions' control
can be moved freely without influencing the members. Normally, when the
members are grouped, their local values of Fader/Mute are left untouched
when the group is formed – they are grouped in a relative way. If absolute
grouping is desired, values can be copied from the master to the members:
• By checking the Copy Enable checkbox and clicking on the Copy but-
ton;
• By completing the editing of a group while the Copy Upon Setup
checkbox is checked.
There is also a context menu available, called up by right-clicking within
the edit dialog:
• If the cursor is placed over the Select items, the menu allows to check
or clear all select boxes;
• If the cursor is placed over the Copy column, the menu allows to check
and clear all copy parameters;
• and if it is placed over a white space, it does both.
Note:
The Control Group Filter dialog box can also be started by clicking on the
Control Group Filter item on the Options menu of the Graphic Controller.
Clicking on the Close button does not terminate the Desk editing mode.