Expander/Gate Parameters On The Lacp - Studer D950 Operating Instructions Manual

Sw v 3.3
Table of Contents

Advertisement

D950 Digital Mixing System
3.3.10.3

Expander/Gate Parameters on the LACP

Example 1 (PAGE 1, GATE):
Dynamics control parameter (Expander/Gate)
ATTENUATION
ATTACK TIME / HYSTERESIS
RELEASE TIME/HOLD
THRESHOLD
3-62 Desk Operation
1
SW
ATTN
AUTO
2
SW
ATCK
AUTO
3
SW
RLSE
AUTO
4
SW
THRS
AUTO
GATE
n–1
1
2
TALK
3
4
LAST MODE
PAGE
FREEZE
SW V3.3
Available operating elements and their function
SW key
=
Gate ON/OFF
Rotary encoder
=
Attenuation setting; MAX., –48 dBFS to 0 dBFS
LED bar
=
Bar display, indicates current attenuation
Center LED
=
On if 0 dBFS is set
Display
=
ATTN; label of control parameter
MAX; indication of attenuation value
– 4; attenuation value –4dBFS
SW key
=
Hysteresis function ON/OFF
ON: 5 dB hysteresis, OFF: 0 dB hysteresis
Rotary encoder
=
Attack time adjustment; 0.2 ms to 1 ms
LED bar
=
Dot display, indicates adjusted attack time
Center LED
=
no function
Display
=
ATCK; label of control parameter
0.5; attack time set to 0.5 ms
=
HOLD function ON/OFF; ON=150 ms/OFF=0 ms
SW key
Rotary encoder
=
Release time adjustment; 10 ms to 10 s
LED bar
=
Dot display, indicates adjusted release time
Center LED
=
no function
Display
=
RLSE; label of control parameter
100m; release time set to 100 ms
1s; release time set to 1 s
=
no function
SW key
Rotary encoder
=
Threshold adjustment; 0 to –96 dBFS, 1 dB steps
LED bar
=
Bar display, indicates threshold
Full bar = 0 dB, empty bar = –96 dB
Center LED
=
Is ON if threshold is set to 0 dBFS
Display
=
THRS; label of control parameter
–24; indicates threshold value –24 dBFS
Display
=
Indication of Expander/Gate selection
GATE; gate parameters (page 1)
EXP; expander parameters (page 2)
LFWD; look forward time (page 3)
KEY; common parameters for expander and
gate (page 4)
Date printed: 03.09.03