Regular Maintenance; Air Filters; Removing And Installing The Supply Unit (1.950.601.00) In The Rack; Changing The Air Filter Mat - Studer D950 Operating Instructions Manual

Sw v 3.3
Table of Contents

Advertisement

9.4

Regular Maintenance

9.4.1

Air Filters

9.4.1.1

Removing and Installing the Supply Unit (1.950.601.00) in the Rack

Removing:
Installation:
9.4.1.2

Changing the Air Filter Mat

Date printed: 03.09.03
Before you start set the DC OUTPUT switch to OFF, also switch off the
mains supply whenever possible.
Loosen the four knurled screws at the front panel; pull out the supply unit
towards the front.
Carefully insert the supply unit into the rack.
Never apply sheer force if the connector contacts do not find their way
easily; check the path to the female contact points inside the rack, it might
be blocked by a foreign object.
Retighten the four knurled screws at the front panel.
DC
OK
DC OUTPUT
ON
OFF
Remove the supply unit as described above.
Place the supply unit onto your working surface in a way that the front
panel is directed towards you.
The wire bracket which fixes the filter mat is hooked into four recesses;
first unhook at the upper right, then at the upper left.
Now the filter mat can be pulled out in upward direction.
For inserting the new filter mat tilt the supply unit to the left. Carefully lift
the lower part of the wire bracket by a small amount with an appropriate
tool (e.g. screwdriver); slide the new filter mat in under the bracket. Make
sure that all the air vents are covered by the filter mat and readjust it, if
necessary.
Bring the supply unit in an upright position again and hook the wire
bracket first at the left, then at the right-hand side.
Recheck that all the air vents are covered by the filter mat.
Reinstall the supply unit as described above.
SW V3.3
D950 Digital Mixing System
Troubleshooting/Maintenance 9-11
Filter mat
Wire bracket
Front panel,
front view

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents