D950 Digital Mixing System
3.3.4.2
Direct Output Parameters
3.3.4.3
N–1 Output Parameters
3-24 Desk Operation
The Output Section enables the user to control the level of the Direct Out-
put.
DIR OUT:
Direct output ON/OFF.
LEVEL:
Direct Output send level, MUTE (i.e. –∞ dB) to +10 dB. Gain range:
• –90 through –80 dB, in steps of 2 dB;
• –80 dB through –20 dB, in steps of 1 dB;
• –20 dB through –10 dB, in steps of 0.5 dB;
• –10 dB through +10 dB, in steps of 0.1 dB.
Note:
0.5 dB are denoted by a decimal point that is not followed by another
number.
0.1 dB increments are always followed by the 1/10
For example, –19.5 dB is displayed as "–19.", and –9.4 is displayed as
"–9.4".
The N–1 Section enables the user to control the level of the N–1 Output,
provided that an N–1 output has been configured for this channel.
N–1 OUT:
N–1 output ON/OFF.
LEVEL:
N–1 Output send level, MUTE (i.e. –∞ dB) to +10 dB. Gain range:
• –90 through –80 dB, in steps of 2 dB;
• –80 dB through –20 dB, in steps of 1 dB;
• –20 dB through –10 dB, in steps of 0.5 dB;
• –10 dB through +10 dB, in steps of 0.1 dB.
Note:
0.5 dB are denoted by a decimal point that is not followed by another
number.
0.1 dB increments are always followed by the 1/10
For example, –19.5 dB is displayed as "–19.", and –9.4 is displayed as
"–9.4".
SW V3.3
th
-dB value.
th
-dB value.
Date printed: 03.09.03