Touch Hold - Studer D950 Operating Instructions Manual

Sw v 3.3
Table of Contents

Advertisement

5.7.3

Touch Hold

D950:
Held Controls:
Date printed: 27.08.03
<Option>
• With <Read Safe> checked on the Misc. Options page, AUDITION
mode is defeated for controls in READ, and only written values will be
heard.
• The TOUCH RECORD key may be overridden by checking options on the
<Master Panel Overrides> section of the Master Panel Options page.
Faders and Encoders can have TOUCH RECORD set to <ON>, <OFF>,
or to follow the Master Panel <Follows Panel>. TOUCH RECORD for
Switches can also have <ON> and <OFF> overrides or be set to follow
the Master Panel <Follows Panel>.
With TOUCH HOLD engaged, touching a control will change it to being in a
"Held" state.
Controls that are in Held status have specific functional qualities:
• They maintain their current status when physically released (Un-
touched)
• They may be selected as a group (Held Objects) for additional automa-
tion operations (such as a Pre-Selector set).
When TOUCH HOLD is activated the Touch event is registered by the sys-
tem and the Un-touch event is suppressed. Touching a control will change
it to the next mode available. More importantly, the control will "hold"
that mode when it is released.
When released, a control in RECORD will not punch-out and change back
to ENABLE, it will stay in RECORD. Likewise a control in AUDITION
will not revert to READ when released.
SW V3.3