Debugging and Diagnostics
The basic debugging and diagnostic commands are supported by the Dell Networking Operating System
(OS) on the S4810 platform.
This chapter contains the following sections:
•
Offline Diagnostic Commands
•
Buffer Tuning Commands
•
Hardware Commands
Offline Diagnostic Commands
The offline diagnostics test suite is useful for isolating faults and debugging hardware. While tests are
running, Dell Networking OS results are saved as a text file (TestReport-SU-X.txt) in the flash directory.
This show file command is available only on master and standby.
Important Points to Remember
•
Offline diagnostics can only be run when the unit is offline.
•
You can only run offline diagnostics on a unit to which you are connected via the console. In other
words, you cannot run diagnostics on a unit to which you are connected to via a stacking link.
•
Diagnostic results are printed to the screen. Dell Networking OS does not write them to memory.
•
Diagnostics only test connectivity, not the entire data path.
diag stack-unit
Run offline diagnostics on a stack unit.
S4810
Syntax
diag stack-unit number [alllevels | level0 | level1 | level2]
verbose testname
Parameters
number
alllevels
level0
Debugging and Diagnostics
Enter the stack-unit id.
Range: S4810 - 0 to 11
Enter the stack-unit number. The range is from 0 to 7.
Enter the keyword alllevels to run the complete set of
offline diagnostic tests.
Enter the keyword level0 to run Level 0 diagnostics. Level
0 diagnostics check for the presence of various components
14
595