Parameters
log
threshold-in
msgs count
interval
minutes
monitor
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is five minutes. By default,
flow-based monitoring is not enabled.
Command
ACCESS-LIST
Modes
Command
Version 9.4(0.0)
History
Version 9.3(0.0)
Usage
When the configured maximum threshold is exceeded, generation of logs is
Information
stopped. When the interval at which ACL logs are configured to be recorded
expires, the subsequent, fresh interval timer is started and the packet count for that
new interval commences from zero. If ACL logging was stopped previously
because the configured threshold is exceeded, it is re-enabled for this new interval.
If ACL logging is stopped because the configured threshold is exceeded, it is re-
enabled after the logging interval period elapses. ACL logging is supported for
standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure
ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable
logging for ACLs that are associated with egress interfaces.
You can activate flow-based monitoring for a monitoring session by entering the
flow-based enable command in the Monitor Session mode. When you enable this
capability, traffic with particular flows that are traversing through the ingress and
egress interfaces are examined and, appropriate ACLs can be applied in both the
ingress and egress direction. Flow-based monitoring conserves bandwidth by
Access Control Lists (ACL)
Use the no deny tcp {source address mask | any | host ipv6-
address} {destination address | any | host ipv6-address}
command
(OPTIONAL) Enter the keyword log to enable the triggering
of ACL log messages.
(OPTIONAL) Enter the threshold-in-msgs keyword
followed by a value to indicate the maximum number of ACL
logs that can be generated, exceeding which the generation
of ACL logs is terminated. with the seq, permit, or deny
commands. The threshold range is from 1 to 100..
(OPTIONAL) Enter the keyword interval followed by the
time period in minutes at which ACL logs must be generated.
The time interval range is from 1 to 10 minutes.
(OPTIONAL) Enter the keyword monitor when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the monitored
interface.
Added support for flow-based monitoring on the S4810,
S4820T, S6000, and Z9000 platforms.
Added support for logging of ACLs on the S4810, S4820T,
and Z9000 platforms.