enable xfp-power-updates

Enable 10–gigabit small form-factor pluggable (XFP) power updates for SNMP.
S4810: Deprecated
Syntax
enable xfp-power-updates interval seconds
Parameters
interval
seconds
Defaults
Disabled
Command
CONFIGURATION
Modes
Command
This guide is platform-specific. For command information about other platforms,
History
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
8.3.19.0
Version 8.3.11.4
Version
8.3.10.0
Version 8.1.1.0
Version 7.6.1.0
Version 7.5.1.0
Usage
The chassis MIB contains the entry chSysXfpRecvPower in the chSysPortTable
Information
table. Periodically, IFA polls the XFP power for each of the ports and sends the
values to IFM where it is cached.
To enable polling and to configure the polling frequency, use this command.
100
Enter the keyword interval then the polling interval in
seconds. The range is from 120 to 6000 seconds. Default:
300 seconds (5 minutes).
Deprecated command for S4820T. Replaced by the enable
optic-info-update interval command to update
information on temperature and power monitoring in the
SNMP MIB.
Deprecated command for Z9000. Replaced by the enable
optic-info-update interval command to update
information on temperature and power monitoring in the
SNMP MIB.
Deprecated command for the S4810 only. Replaced by the
enable optic-info-update interval command to
update information on temperature and power monitoring in
the SNMP MIB.
Introduced on the E-Series ExaScale.
Introduced on the S-Series.
Introduced on the C-Series and E-Series.
Control and Monitoring