Automatic Transmission
Shift Solenoid Valve B Test
1. Disconnect the connector from the shift solenoid
valve B.
2. Measure shift solenoid valve B resistance at the
solenoid valve connector (blown).
Standard: 12 25
3. Replace the shift solenoid valve B if the resistance
is out of standard.
4. If the resistance is within the standard, connect the
No. 2 terminal of the shift solenoid valve B
connector to the battery positive terminal, and
connect the No. 1 terminal to the battery negative
terminal. A clicking sound should be heard.
Replace the shift solenoid valve B if no clicking
sound is heard.
14-358
14-358
Shift Solenoid Valve B Replacement
1. Remove the mounting bolt and the shift solenoid
valve B.
6 x 1.0 mm
12 N·m (1.2 kgf·m, 8.7 lbf·ft)
2. Install a new shift solenoid valve B (A) with new O-
rings (B). When installing the solenoid valve, do not
allow dust or other foreign particles to enter the
transmission.
3. Check the connector for rust, dirt, or oil, then
reconnect it.
A
B