HEATER VALVE AND FRESH AIR DOOR CABLE
ADJUSTING
This cable controls the heater valve and fresh air door.
Position
sliding knob
MAX. COLD
INTERMEDIATE
MAX. HOT
Fresh air door
Open
Closed
Closed
Heater valve
Closed
Closed
Open
• Attach cable (8) to heater valve (9).
• Clip outer sleeve (10).
• Attach cable (8) to sliding knob (11).
• Set the heater valve in the "Off"
position.
• Set sliding knob (11) to "Max. Cold" position.
• Clip outer sleeve (12).
- If the cable cannot be clipped in this position,
reset it at the heater valve end.
- Check the operation by sliding the control knob
and observing that both the heater valve and
the fresh air door open and close correctly.
1
J
!
.1
MS-1