COMPONENTS
HYDRAULIC CONTROL UNIT (VALVE BODY)
14
.~
,W
j
)
1
1
'C~1
REFITTING
• Attach clip (E) to the sealed connector socket and
reconnect socket.
• Fit manually operated valve (14) in the center line
of the toothed quadrant.
• Place the
vacuum
capsule
on the
pressure
regulating valve (11).
• Screw in bolts (2) and (6) on the control unit as
far as they will go since they determine the
position of the control unit when all the bolts
have been tightened.
• Using a torque wrench, tighten
the hydraulic
control unit bolts to 0.9 daNm (6.5 Ib.lft.) in the
order shown.
• After tightening
bolts (1) to (6), install the new
filter screen and seal as shown in the illustration.
• Attach the pan equipped with a new gasket.
• After
installing,
check
that
the
manually
operated valve moves correctly.
• Fill with fluid and adjust the fluid pressure.