DIAGNOSTICS
FAULT • CORRECTION CHART
Stays in 3rd or gears change at random
and
warning light does not illuminate
FAULT - PROBABLECAUSE
CHECKS· CORRECTIVE ACTION
1. Lack of ground or poor ground to computer
Check grounding at the multipurpose switch. Check
the vehicle wiring
harness.
2. Kick-down
switch wire poorly connected or Check routing and condition of kick-down switch
damaged wire affecting ground.
wire.
No park function in "P"
J
F'
[:.J
FAULT - PROBABLE CAUSE
1. Badly adjusted selector lever
CHECKS - CORRECTIVE ACTION
Adjust selector lever
!'\
' . . j
2. Ratchet arm and its spring and internal control
Check the various parts
device defective
Starter inoperative in "N" or "P"
FAULT - PROBABLE CAUSE
CHECKS- CORRECTIVE ACTION
Check the battery charge and the condition of its
terminals to ensure that they are clean
Adjust the selector lever
Check that the multipurpose switch is operating
correctly. Perform test using XR25
starter
Check the
voltage
at the
6-way
connector
at
computer with the starter activated - The ground
wire at the multipurpose switch.
Check the starter relay
Check the key switch
Check the starter
F2-12