1
DIAGNOSTIC
CHECKING CONNECTIONS
Step 2
Disconnect the 6-way connector at the computer
and make the following
measurement using an
ohmmeter.
•
-
-
-
-
Measuring points
Between the battery - (- on terminal) and point E
on computer connector
1. Check connection and condition of terminal
(G) ground lead on automatic transmission
housing.
2. Check continuity
of ground
lead (using
ohmmeter) placed between terminal (G) and
point
(E)
on connector on computer. Correct
result should
be between
0 and 0.5. If
incorrect, change the multi-purpose switch or
computer depending on where the lead is
damaged.
F2-27
Result
0-0.5
OTHER
Diagnosis
GOOD
NCORRECT
See' - 2 - 0