Sflow Polling (Interface Mode) - Dell PowerEdge M420 Reference Manual

Dell powerconnect m6220/m6348/m8024/m8024-k cli reference guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

Default Configuration
There are no pollers configured by default.
The default poll interval is 0.
Command Mode
Global Configuration mode.
User Guidelines
This command has no user guidelines.
Example
console(config)#sflow 1 polling gigabitethernet
1/0/1-10 200

sflow polling (Interface Mode)

Use the sflow polling command in Interface Mode to enable a new sflow
poller instance for this data source if rcvr_idx is valid. Use the "no" form of
this command to reset poller parameters to the defaults.
Syntax
rcvr-index
sflow
rcvr-index
no sflow
rcvr-index — The sFlow Receiver associated with the poller (Range: 1 - 8).
poll-interval — The sFlow instance polling interval. A poll interval of 0
disables counter sampling. A value of n means once in n seconds a counter
sample is generated. (Range: 0 - 86400).
Default Configuration
There are no pollers configured by default.
The default poll interval is 0.
Command Mode
Interface Configuration (Ethernet) mode
1464
Sflow Commands
poll-interval
polling
polling

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents