Snmp-Server Engineid Local - Dell PowerEdge M420 Reference Manual

Dell powerconnect m6220/m6348/m8024/m8024-k cli reference guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

multiple-users
multiple logins
ospf
ospfv3
pim
spanning-tree
Tree traps.

snmp-server engineID local

Use the snmpserver engineID local command in Global Configuration mode
to specify the Simple Network Management Protocol (SNMP) engine ID on
the local device.
To remove the configured engine ID, use the no form of this command.
Syntax
snmp-server engineID local {
no snmp-server engineID local
engineid-string — The character string that identifies the engine ID. The
engine ID is a concatenated hexadecimal string. Each byte in hexadecimal
character strings is two hexadecimal digits. Each byte can be separated by
a period or colon. (Range: 6-32 characters)
default — The engineID is created automatically, based on the device
MAC address.
Default Configuration
engineID
The
is not configured.
Command Mode
Global Configuration mode
Enable/Disable sending traps when
active.
Enable/Disable OSPF Traps.
Enable/Disable OSPF Traps.
pim
Enable/Disable sending Spanning
engineid-string
| default }