User Guidelines
Upon execution, the entire stack, including all interfaces in the stack, are
unconfigured and reconfigured with the configuration on the new
Management Switch.
NOTE: The switch always starts up from the startup-config and not the running-
config. To start up from the running-config, use the initiate failover command.
After the reload is complete, all stack management capability must be
performed on the new Management Switch.
To preserve the current configuration across a stack move, execute the copy
configuration command before performing the stack move. A stack move
causes all routes and layer 2 addresses to be lost. This command is executed
on the Management Switch. The administrator is prompted to confirm the
management move.
Example
The following example displays how to move the Management Switch
functionality from switch "1" to switch "8."
console(config)#stack
console(config-stack)#movemanagement 1 8
nsf
Use this command to enable non-stop forwarding. The "no" form of the
command will disable NSF.
Syntax
nsf
no nsf
Default Configuration
Non-stop forwarding is enabled by default.
Command Mode
Stack Global Configuration mode