Motd-Banner - Dell PowerEdge M420 Reference Manual

Dell powerconnect m6220/m6348/m8024/m8024-k cli reference guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

NOTE:
The "no" form of the command may not be used if the member is present in
the stack.
Syntax
unit switchindex
member
unit
no member
unit — The switch identifier of the switch to be added or removed from
the stack. (Range: 1–12)
switchindex — The index into the database of the supported switch types,
indicating the type of the switch being preconfigured. The switch index is
a 32-bit integer obtained from the show supported switchtype command.
Default configuration
This command has no defaults.
Command Mode
Stack Global Configuration
User Guidelines
The switch index (SID) can be obtained by executing the show supported
switchtype command in User Exec mode. When removing a unit from a
stack, use the no member command to remove the stack member
configuration after physically removing the unit.
Example
The following example displays how to add to stack switch number 2 with
index 1.
console(config)# stack
console(config-stack)# member 2 1

motd-banner

Use the motd-banner command to enable motd on the console, telnet or
SSH connection. To disable, use the no form of the command.
System Management Commands
1545