following command configures 3600 seconds (1 hour) as the minimum lockout
time and 7200 seconds (2 hours) as the maximum lockout time.
host1(config-subif)#auto-configure bridgedEthernet lockout-time 3600 7200
Assign a profile to match the encapsulation type of bridged Ethernet.
5.
host1(config-subif)#profile bridgedEthernet foo
(Optional) Assign subscriber identification.
6.
host1(config-subif)#subscriber bridgedEthernet user charlie domain myisp password
lucy
(Optional) Verify your configuration.
7.
host1#show atm subinterface atm 2/0.1
Use to configure a PVC on an ATM interface. Select one of the following encapsulation
types:
aal5autoconfig—Enables autodetection of the 1483 encapsulation (LLC/SNAP or
VC multiplexed).
aal5snap—Specifies a LLC encapsulated circuit; the LLC/SNAP header precedes
the protocol datagram.
aal5mux ip—Specifies a VC multiplexed circuit. This option is used for IP only.
Example
host1(config-subif)#atm pvc 6 0 11 aal5autoconfig
Use the no version to remove the specified PVC.
See atm pvc.
Use to configure an ATM subinterface to support a dynamic interface. Specifies the
types of dynamic encapsulation that the ATM 1483 subinterface detects and accepts.
For detailed information about how to use this command, see "auto-configure" on
page 528.
Example 1—Enables autodetection for the bridged Ethernet encapsulation type using
the default lockout time range, 1–300 seconds
host1(config-subif)#auto-configure bridgedEthernet
Example 2—Enables autodetection for the bridged Ethernet encapsulation type using
a nondefault lockout time range of 3600–21600 seconds (1–6 hours)
host1(config-subif)#auto-configure bridgedEthernet lockout-time 3600 21600
Example 3—Disables encapsulation type lockout for the bridged Ethernet encapsulation
type
host1(config-subif)#auto-configure bridgedEthernet lockout-time none