JunosE 11.2.x Link Layer Configuration Guide
show frame-relay pvc
146
Up—Traffic can flow on the interface
Offline—Traffic cannot flow because hardware is unavailable
Down—Traffic cannot flow because of a problem in the interface at the current
protocol layer
LowerLayerDown—Traffic cannot flow because of a problem in an interface at a
lower protocol layer
AdministrativelyDown—Traffic cannot flow because of manual administrative
intervention
Number of multilink interface down transitions—Number of interfaces that have
changed to a down state
Time since last status change—Time since the interface last changed its state
In bytes—Number of inbound bytes received on the interface
In frames—Number of inbound frames received on the interface
In errors—Number of inbound errors received on the interface
In discards—Number of inbound packets discarded
In unknown protos—Number of packets received on the interface with unknown
protocols
Out bytes—Number of outbound bytes transmitted on the interface
Out frames—Number of outbound frames transmitted on the interface
Out errors—Number of outbound errors transmitted on the interface
Out discards—Number of outbound packets discarded
Example
host1#show frame-relay multilinkInterface
Multilink Frame relay interface 6/2:2, status is down
Number of multilink interface down transitions is 0
Time since last status change 2 days, 23 hours
In bytes: 0
In frames: 0
In errors: 0
In discards: 0
In unknown protos: 0
See show frame-relay multilinkInterface.
Use to display statistics about PVCs for Frame Relay interfaces.
Specify a DLCI number or an interface type and location.
Use the optional delta keyword to specify that baselined statistics are to be shown.
Out bytes: 0
Out frames: 0
Out errors: 0
Out discards: 0