interface serial
ip address
Copyright © 2010, Juniper Networks, Inc.
To specify a POS interface for E120 and E320 routers, use the slot/adapter/port format.
slot—Number of the chassis slot
adapter—Identifier for the IOA within the E320 chassis, either 0 or 1, where:
0 indicates that the IOA is installed in the right IOA bay (E120 router) or the upper
IOA bay (E320 router).
1 indicates that the IOA is installed in the left IOA bay (E120 router) or the lower
IOA bay (E320 router).
port—Port number on the IOA
For more information about modules that support POS interfaces, see chapter
Configuring Unchannelized OCx/STMx Interfaces in JunosE Physical Layer Configuration
Guide.
Examples
host1(config-if)#interface pos 0/1
host1(config-if)#interface pos 5/0/0
Use the no version to remove the POS interface.
See interface pos.
Use to specify a serial interface in the slot/port:channel/subchannel format by selecting
a previously configured physical interface on which you want to configure PPP.
slot—Refers to a router chassis slot.
port—Refers to a CT3, T3, or E3 module I/O port.
channel—Refers to a T1 (DS1) channel.
subchannel—Represents a set of DS0 subchannels.
Example
host1(config)#interface serial 3/0:2/5
Use the no version to disable or remove the subinterface or the logical interface.
See interface serial.
Use to assign an IP address and subnet mask for a PPP interface.
Example
host1(config-if)#ip address 192.168.22.10 255.255.255.0
Use the no version to remove an IP address or disable IP processing.
See ip address.