Table 13: show ethernet oam lfm status Output Fields (continued)
Field Name
High Threshold Action
Remote-loopback
Frame-seconds Error Monitor
Window
Low threshold
High threshold
Frame-errors Error Monitor
Window
Low threshold
High threshold
Symbol-errors Error Monitor
Field Description
Action that occurs when the high threshold for an error is
exceeded:
disable—Sets the OAM functionality to unconditionally attempt
to influence the operational state of the interface to down. If
the interface is a member link of a LAG bundle and at least one
other viable link (redundant member or another active/up link)
is present, OAM attempts to influence the operational state of
the link to down. Otherwise, no action is taken
failover—On GE-2 and GE-HDE line modules that are paired
with GE-2 SFP I/O modules with physical link redundancy,
causes the transition of the link from active to redundant
Indicates whether the local interface is enabled for remote
loopback functionality and whether it can respond to remote
loopback requests from peers: supported or unsupported.
An OAM entity can put its remote peer into loopback mode using
the Loopback control OAM PDU. In loopback mode, every frame
received is transmitted back on the same port (except for OAM
PDUs, which are needed to maintain the OAM session) to the
local entity
Displays a detailed classification of frame seconds errors event
TLVs since the OAM sublayer was reset
Specified amount of time in milliseconds during which frame
seconds error events are counted
Lowest value for frame second error events in number of frames,
which when exceeded causes an Errored Frame Seconds
Summary Event TLV to be sent to the peer
Highest value for frame second error events in number of frames,
which when exceeded causes an action to be triggered
Displays a detailed classification of frame errors event TLVs since
the OAM sublayer was reset
Specified amount of time in hundred-millisecond units during
which frame error events are counted
Lowest value for frame error events in number of frames, which
when exceeded causes an Errored Frame Event TLV to be sent
to the peer
Highest value for frame error events in number of frames, which
when exceeded causes an action to be triggered
Displays a detailed classification of symbol errors event TLVs
since the OAM sublayer was reset
Copyright © 2010, Juniper Networks, Inc.