Delayed Short
set_trigger
List Command
Comments
• Signal1, Signal2 = 0, 24 and 31...42 enables logging of values that were outputted
during the previous clock cycle. During the current clock cycle, the corresponding
signals may change after logging, either automatically or via control and list
commands.
• Signal1, Signal2 = 24 enables logging of the signal parameter that will be automat-
ically adjusted during position- and/or speed-dependent or encoder-speed-dependent
laser control (see set_auto_laser_control). Logging only occurs when automatic laser
control has been activated and the laser is on. For switched-off lasers, 0 is logged.
• Signal1, Signal2 = 31 enables logging of the signal parameter specified for vector-
defined laser control (see set_vector_control). Logging is also possible without
executing para commands, but then the signal values remain unchanged.
• Pulse length and output period (Signal1, Signal2 = 37, 38) will only be logged for
"Laser active" laser control signals (not standby signals). In softstart mode (see
page
might possibly change faster than the 10 µs clock period (time resolution of logging via
set_trigger).
• For Signal1, Signal2 = 39...42 see
®
®
RTC
4 RTC
5 unchanged basic functionality (measurement storage), however:
• The measurement session can be aborted (unlike with the RTC
previously acquired measurement values (see Period = 0 above).
• The RTC
either SampleAZ_Corr or SampleBZ_Corr (Signal1/2 = 12, 15) simultaneously supplies
a meaningful signal (also see the above information on 3D systems).
• The Sample<X...Z> and Sample<AX...BZ>_Corr signals have a different meaning on the
®
RTC
5 than on the RTC
• On the RTC
within the range [–2
values transmitted to the scan system are in the shifted range of [0 ... (2
latter also applies if the scan system is controlled by a RTC
XY2-100 converter (also see
Version info
Last change with version DLL 536, OUT 536: Signal1, Signal2 = 43 and 44
get_waveform, measurement_status, control_command, get_value, get_values,
References
set_mcbsp_out, set_mcbsp_out_ptr,
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
135) and in pixel-output mode (see
®
5 has no StatusAZ and StatusBZ (RTC
®
4 (see information above).
®
5, all coordinate values are relative to the image field centerpoint 0 and lie
19
19
... (2
1)]. For the RTC
page
page
192), the pulse length and output period
chapter 6.9.1 "Free Variables", page
®
4: Signal1/2 = 3, 6) signals. Only
®
4, in contrast, the effective output
®
5 in conjunction with the
126).
set_trigger4
92.
®
4) without losing the
16
1)]. The