Delayed Short
save_and_restart_timer
List Command
Function
stores the current value of the RTC
Call
save_and_restart_timer()
Comments
• The stored timer value can be read by the
• The command is useful for measuring the marking time of a marking process.
• The timer only counts list-command clock cycles. The counter is paused during an inter-
ruption via
• To compare RTC
time measurements via the BUSY pin, you should insert a
save_and_restart_timer and set_end_of_list. This ensures that any scanner delay will
complete before set_end_of_list. Without list_nop, save_and_restart_timer includes
the scanner delay in its measurement even though it completes only after
set_end_of_list
®
®
RTC
4 RTC
5 unchanged
References
get_time
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
®
5 timer and resets it to zero
set_wait
or pause_list.
®
5-internal save_and_restart_timer time measurements to external
(and therefore the BUSY pin is already low).
get_time
command.
list_nop
between