Ctrl Command control_command
Code
15
17
21
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
Command and Parameter Values (Code
H
SetPosAcknowledgelevel (as of Firmware Version 2066):
H
This command sets the PosAcknowledge threshold value (also see
parameter value Code
[00
... FF
]. Also see comments
H
H
Store/RestoreTransmissionMode (as of Firmware Version 2078):
H
This command allows the currently used status return data type to be temporarily
stored (Code
= FF
) and then reinstated at a later time (Code
L
H
Code = 0527
.
H
SetEchoMode (as of Firmware Version 2078):
H
This command verifies whether data transfer is intact (also see
transfers an 8-bit value (Code
returned on the corresponding status channel: if data transfer is error-free, then
the upper 8 bits of the returned 20-bit value will be identical with Code
next lower 8 bits will be identical with the complement of Code
Example: For control_command(1, 1, 0x210A) and if data transfer is error-free,
(get_value(1) AND 0xFFFF0) returns 0x0AF50.
)
L
is the desired PosAcknowledge threshold value in bits
L
page
253.
) to the scan system and causes a 20-bit value to be
L
page
160). The
= 00
). Also see
L
H
page
161). It
and the
L
(NOT Code
).
L
L
250