Scanlab RTC 5 PC Interface Board Installation And Operation Manual page 433

Table of Contents

Advertisement

Ctrl Command set_free_variable
Function
sets a free variable to the desired value.
Call
set_free_variable( No, Value )
Parameters
No
Value
Comments
• See
chapter 6.9.1 "Free Variables", page
®
®
RTC
4 RTC
5 new command
Version info
Available beginning with version DLL 531, OUT 532
References
set_free_variable_list, get_free_variable,
Undelayed
set_free_variable_list
Short
List Command
Function
same as
Call
set_free_variable_list( No, Value )
Parameters
No
Value
Comments
• See set_free_variable.
®
®
RTC
4 RTC
5 new command
Version info
Available beginning with version DLL 531, OUT 532
References
set_free_variable
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
Number of the free variable to be set as an unsigned 32-bit value.
Allowed range: [0 ... 3]
Only the two least significant bits are evaluated.
Desired variable value as an unsigned 32-bit value.
Allowed range: [0 ... (2
set_free_variable
(see above), but a list command
See set_free_variable.
See set_free_variable.
32 –
1)]
92.