Ctrl Command set_serial
Function
sets the starting serial number of the serial-number-set most recently selected via
select_serial_set
increment size for this serial-number-set to 1.
Call
set_serial( No )
Parameters
No
Comments
• The command set_serial is synonymous with
comments there).
®
®
RTC
4 RTC
5 unchanged functionality (except for the extended range of values)
(the command was previously only available for the RTC
standalone version of the RTC
References
set_serial_step,
Ctrl Command set_serial_step
Function
sets the starting serial number and the increment size for the serial-number-set most
recently selected via
load_program_file).
Call
set_serial_step( No, Step )
Parameters
No
Step
Comments
• During initialization, the starting serial number is set to 0 and the increment size set to
1.
• If
mark_serial
number incrementing was deactivated), then the increment size setting will have no
effect.
• If Step = 0, then incrementing will not occur, except in the case of markless marking
(see
mark_serial
numbers by 1.
• For command usage, see
®
®
RTC
4 RTC
5 new command
References
mark_serial, mark_serial_abs, set_serial, select_serial_set,
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
(or of serial-number-set 0 after load_program_file) and sets the
Serial number as an unsigned 32-bit value;
32
allowed range: [0 ... (2
–1)]
®
4 board)
select_serial_set
select_serial_set
(or for serial-number-set 0 after
Serial number as an unsigned 32-bit value; allowed range: [0 ... (2
Increment size as an unsigned 32-bit value;
allowed range: [0 ... 9999]; only the last 4 decimal digits are used.
or
mark_serial_abs
was called with Mode M
or mark_serial_abs: digits = 0), which always increments serial
chapter 7.5.2 "Marking Serial Numbers", page
set_serial_step
with Step = 1 (see
®
SCANalone Board, i.e. the
= 1 (i.e. automatic serial-
2
150.
select_serial_set_list
32
–1)]