Normal
apply_mcbsp_list
List Command
Function
same as
Call
apply_mcbsp_list( HeadNo, at_once )
Parameters
HeadNo
at_once
Comments
• See apply_mcbsp.
®
®
RTC
4 RTC
5 new command
Version info
Available beginning with version DLL 524, OUT 526
References
apply_mcbsp
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
apply_mcbsp
(see above), but a list command
See apply_mcbsp.
This parameter (unsigned 32-bit value) determines when the defined
transformation becomes effective:
= 0:
The transformation settings are only collected and intermediately
stored, but the transformation is not processed as long as this is not
activated via another coordinate transformation (e.g. via a list
command with at_once = 1 or a corresponding control command).
= 1:
The transformation is immediately calculated (including all
transformation settings that were collected until then) and processed
prior to the next list command.
= 2:
The transformation settings are only collected and intermediately
stored (as with at_once = 0). However, The transformation is
immediately calculated (including all transformation settings that
were collected and intermediately stored until then) and applied to
the current position when the next jump_abs, jump_rel,
goto_xyz
command is executed.
> 2:
See at_once = 2
goto_xy
or
231
Need help?