Scanlab RTC 5 PC Interface Board Installation And Operation Manual page 267

Table of Contents

Advertisement

Ctrl Command get_head_status
Comments
• Status signals can also be queried via get_value, get_values,
set_trigger4.
• Also see
®
®
RTC
4 RTC
5 essentially unchanged functionality, however:
• The RTC
connectors' status words, even (for iDRIVE
to be returned selected via control_command.
• Even for iDRIVE
information about the scan system's operational readiness (see get_value).
References
get_value, get_values, set_trigger, set_trigger4,
Ctrl Command get_hex_version
Function
returns the version number of the currently loaded RTC
RTC5OUT.out)
Call
HexVersion = get_hex_version()
®
Result
RTC
5 software version number as an unsigned 32-bit value
Comments
• The version numbers of program files are in the range 500 ... 599.
get_hex_version returns the following values:
– if the 3D option is not enabled:
values in the range 2500 ... 2599 (version number + 2000)
– if the 3D option is enabled:
values in the range 3500 ... 3599 (version number + 3000)
• The file name extension for RTC
®
RTC
3 and RTC
• For DLL 535 and higher: The software version number can also be returned after an
RTC5_VERSION_MISMATCH or RTC5_ACCESS_DENIED error. The return value is 0 if no
program has yet been loaded. Here, an RTC5_TIMEOUT error will not be generated.
®
®
RTC
4 RTC
5 unchanged functionality
Version info
Last change with version DLL 535 (see comment)
References
get_dll_version,
Ctrl Command get_hi_data
Function
returns the Home-In positions, last determined (via auto_cal) of the scan system attached
to the primary scan head connector.
Call
get_hi_data( &X1, &X2, &Y1, &Y2)
Returned para-
X1, X2,
meter values
Y1, Y2
Comments
• The command is synonymous with the
comments there).
®
®
RTC
4 RTC
5 unchanged functionality (except for the extended range of values).
The returned values are in the RTC
References
get_hi_pos
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
chapter 8.5, page 170
for information about using two scan heads.
®
®
5 allows (unlike the RTC
®
scan systems, bits #0 and 1 (unlike with the RTC
®
5 program files is no longer *.hex (as with the RTC
®
2), but instead *.out (also see
get_rtc_version
coordinates of the currently stored Home-In positions in bits as pointers to
signed 32-bit values
®
5's 20-bit range.
set_trigger
4) the simultaneous reading of both scan head
®
scan systems) independently of the signal
get_waveform
®
5 software (DSP program file
load_program_file, page
get_hi_pos
command with HeadNo = 1 (see
and
®
4) do not return
®
4,
340).
267

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTC 5 PC Interface Board and is the answer not in the manual?

Related Products for Scanlab RTC 5 PC Interface Board

Table of Contents

Save PDF