monitoring XY positioning because it's only
meant for querying a single signal and multiple
calls unavoidably lead to XYZ values across
different points of time.
• With set_trigger, you can simultaneously record
two desired signals via two measurement
channels (with
set_trigger4
measurement channels).
• With
transform
and get_transform, you can use
the parameter Code to specify that values queried
via
get_values
or
set_trigger
to X, Y and Z for backward transformation.
•
transform
and
get_transform
cation of which partial transformations should be
performed.
• Values queried via get_values, or arbitrary
synthetic values (e.g. measurement points of a
scanned test pattern) can actually be backward
transformed with transform. During backward
transformation of synthetic values beyond the
forward transformation's achievable image field
(e.g. when test pattern measurements don't use
SCANLAB's reference system, see
values sometimes will only be calculated via
extrapolation, due to possible range violations or
other errors.
• If the application binarily stores both the
recorded values and the transferred transfor-
mation data (see get_waveform), then subse-
quent backward transformation via
(not get_transform) can also be executed offline,
hence without needing to further access a RTC
board.
• If
control_command
is used to specify
positioning error rather than actual position as
the to be returned data type by the scan system,
then it isn't possible to directly compare the origi-
nally defined pattern with the scanned pattern.
But you can check if the scan system correctly
®
processed the RTC
5 board's output values. This
is particularly useful if backward transformation
of actual values isn't (fully) possible or when it
can't be determined if deviations between
backward-transformed actual positions and origi-
nally defined coordinate values are due to scan
system error or clipping during forward transfor-
mation.
®
RTC
5 PC Interface Board
Rev. 1.9 e
8 Advanced Functions for Scan Head and Laser Control
8.1.4 Configuring Dynamics Settings
SCANLAB can optimize the dynamics setting of scan
systems (tuning) to accommodate differing require-
ments of diverse applications regarding the laser
positioning dynamics
four signals via four
circular arcs at a constant processing speed (vector
tuning) or to execute jumps of minimized duration
(jump tuning).
SCANLAB's iDRIVE
are to be assigned
optionally equipped with multiple tunings (i.e. with
several parameter sets or algorithms), thus allowing
also allow specifi-
user selection of appropriate tunings matched to
each of their various applications. You can select a
tuning via control_command. For systems equipped
with one or several jump tunings, you can also
activate jump mode (and hereby tuning
autoswitching) for 2D jumps (see
The default start behavior is for the scan system to
start with its first tuning (number 0) upon power-up
or after a reset.
page
118),
transform
®
5
(Tuning)
e.g. to execute vectors or
–
®
scan systems can also be
page
156).
155
Need help?
Do you have a question about the RTC 5 PC Interface Board and is the answer not in the manual?