Ctrl Command load_z_table
®
®
RTC
4 RTC
5 unchanged functionality (except for changed value ranges and error codes)
If the correct calibration factors are used (see
can be used on the same 3-axis scan system with the RTC
Version info
Last change with version DLL 516
References
get_z_distance
Normal
long_delay
List Command
Function
pauses further processing of the list for the specified time
Call
long_delay( Delay )
Parameter
Delay
Comments
• This command (if applicable) switches off the "laser active" laser control signals after a
LaserOff delay, waits for a possible scanner delay and pauses further processing of the
list for the specified time.
• This command should always be called after changing the lamp current of a YAG laser
to obtain a constant laser power.
• The command
®
®
RTC
4 RTC
5 unchanged functionality (except for the increased range of values)
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
delay time in bits as an unsigned 32-bit value.
1 bit equals 10 µs. Allowed range: 0 delay (2
list_nop
corresponds to long_delay( 1 ).
page
172), then the same ABC coefficients
®
®
4 and RTC
5 boards.
32
–1).
348
Need help?
Do you have a question about the RTC 5 PC Interface Board and is the answer not in the manual?