• If the 3D option is not enabled or no 3D
correction table has been assigned, then 3D
marking commands will have the same effect as
2D marking commands. However, microvector-
ization will be calculated like a 3D command and
hence will influence the effective jump or
marking speed in the XY plane.
• If the 3D option is not enabled or no 3D
correction table has been assigned, then 3D
vector commands will have the same effect as 2D
vector commands. However, microvectorization
will be calculated like a 3D command and hence
will influence the effective jump or marking speed
in the XY plane (this doesn't apply to the 3D arc
commands
arc_abs_3d
set_offset_xyz
or
set_offset_xyz_list
used for setting an offset z
In addition,
set_defocus
be used for defining an offset to the calculated
focal length, which will then appropriately affect
the Z output value (in the direction opposite to
z
).
0
• During a marking process (while a mark or arc
command is being processed), the scan system's
focal length is continuously readjusted, so that
the laser focus remains sharp within the current
image plane. In contrast, during execution of a
jump command (or goto_xyz) readjustment of
the focus is not really necessary. Therefore, the
commands
set_delay_mode
set_delay_mode_list
allow defining the value of
its DirectMove3D parameter to provide a jumping
method that changes the Z output value directly
(linearly) from its start value to its end value. This
can help to avoid needless movements of the Z-
axis.
®
RTC
5 PC Interface Board
Rev. 1.9 e
8 Advanced Functions for Scan Head and Laser Control
and arc_rel_3d).
can be
for the Z coordinate.
0
or
set_defocus_list
can
and
• For 3D marking commands, the following
settings (if made) directly affect the X and Y
output values, but have no effect or only an
indirect effect on Z output values (also see
page
126):
– a wobbel motion enabled via
set_wobbel_mode
(see
– a Processing-on-the-fly correction enabled via
set_fly_x, set_fly_y,
set_fly_rot
set_fly_x_pos, set_fly_y_pos,
(see
page
177).
– a coordinate transformation for the X and Y
output coordinates defined via set_matrix,
set_offset,set_offset_xyz, set_scale,
set_angle
or corresponding list commands (see
page
161).
– a gain and offset correction activated via
auto_cal
or
set_hi
(see
• The RTC®5 command set also includes 3D micro
vector commands (see
page
set_wobbel
or
page
167).
or
set_fly_rot_pos
page
199).
197).
173