Regular (Periodic) External List Starts
Note
• This functionality requires a firmware file in
version 507 or higher (see get_rtc_version) and a
DSP program file in version 511 or higher (see
get_hex_version).
Via
set_control_mode
and
(bit #10), equidistant external list starts can be
created that are independent of the time point of the
start trigger as long as they occur within the specified
track delay. This strongly periodic list processing is –
independently of a list's actual duration of execution
and the exact time point of the external list start –
exactly synchronized to the RTC
If desired, set bit #10 = 1 (Mode|Bit#10) to configure
the internal encoder-counter's processing so that the
track delay of an external list start will not be counted
only beginning with the time point of the triggering
simulate_ext_start
external start signal or
(bit #10 = 0) but already beginning with the most
recently executed external list start (also executed via
an external start signal or
simulate_ext_start
command) – see
figure
59.
For activation of this mode, an external list start must
have successfully occurred (only one-time) in mode
~
bit #10=0 (Mode &
Bit#10). Each subsequent
external list start must be requested within the spec-
ified track delay.
Example (in PASCAL) of a typical command sequence
(without use of an external start signal):
set_control_mode(Mode &
Bit #10 = 1:
Execution
time
Start
Bit #10 = 0:
Execution
time
Start
Regular and irregular external list starts (see text for description)
®
RTC
5 PC Interface Board
Rev. 1.9 e
9 Programming Peripheral Interfaces
set_control_mode_list
®
5's 10 µs clock.
command
~
Bit#10);
Track delay
Track delay
1
Execution
time
Start
Track delay
1
Start
1
simulate_ext_start
2
// (one-time) reset (disable) bit #10 (initialization)
set_start_list_pos(ListNo, Pos);
// open some list
// afterward: some commands
simulate_ext_start(Delay,EncoderNo);
// first time start in mode bit #10 = 0, otherwise in
// mode bit #10 = 1
set_control_mode_list(Mode|Bit#10);
// set bit #10 = 1
// afterward: further commands
set_end_of_list;
// close the list
execute_list_pos(ListNo,Pos);
// (one-time) start the list
If the first start is to be triggered externally (e.g. via
/START or via simulate_ext_start_ctrl) rather than via
an
execute_list_pos
command, but all subsequent
starts triggered via simulate_ext_start, then
set_control_mode_list
in the above example must
be called before simulate_ext_start.
As of Version DLL 528, OUT 530, after setting
set_control_mode
bit#1 = 1, the external start
queue's entries get explicitly cancelled upon an
external list stop (thereby, external starts can be
permanently stopped via an external list stop).
For older versions and for set_control_mode,
bit #1 = 0 (default setting) – after an otherwise infi-
nitely repetitive series has been stopped (e.g. via
set_control_mode, bit #0 = 0) – you should deac-
tivate the track delay and cancel the queue of not-
yet-executed external list starts via
set_ext_start_delay
(Delay = 0). Otherwise, the next
"equidistant" external start won't have the correct
Track delay
2
Execution
time
Start
Track delay
2
Execution
time
/START, /START2 or /Slave-START
Start
Time
Start
Time
59
212