Undelayed
list_repeat
Short
List Command
Function
initiates repetition of a group of list commands.
Call
list_repeat()
Comments
• See
chapter 6.5.5 "Loops", page
• Any still-pending delayed short list command will execute first.
• All list commands between this command and the next
possibly repeated multiple times.
• Nesting up to 8
command beyond that limit will be ignored as long as no
loop.
• If a list terminates (via
fully-processed
an automatic list change (via auto_change,
• Complete
between lists and subroutines or between different subroutines is not permitted.
Changing between lists is permitted as long as the list change occurs without explicit
list termination (via an automatic list change or via an explicit list jump to another list
with list_jump_pos).
• List jumps into a
external location should be avoided. Careless use could compromise loop management
integrity so severely that loops won't execute as expected. But subroutine calls from
inside a loop are always reliably possible.
®
®
RTC
4 RTC
5 new command
Version info
Available beginning with version DLL 536, OUT 536
References
list_until
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
82.
list_repeat/list_until
set_end_of_list
list_repeat/list_until
loops will be deleted. However, this won't occur if
list_repeat/list_until
loops can reside within a list or subroutine. Changing
list_repeat/list_until
list_until
loops deep is allowed. Each further list_repeat
list_until
or
stop_execution
or /STOP), then all not-yet-
auto_change_pos
or start_loop) is active.
loop's body or from inside a loop to a loop-
command will be
has terminated a
323