8-Bit Digital Output Port; 12-Bit Analog Output Ports - Scanlab RTC 5 PC Interface Board Installation And Operation Manual

Table of Contents

Advertisement

9.1.2 8-Bit Digital Output Port

The EXTENSION 2 connector provides a (jumper-
configurable) buffered 8-bit digital output port
(DATA0 to DATA7) (see
page
Its output values can be set via
write_8bit_port_list. The output is in high-
impedance mode (tri-state) until an initial value is
assigned to it. In addition, the commands
set_port_default
(Port = 2) or
set_laser_off_default
can be used to define the
value to be outputted at the 8-bit digital output port,
as soon as processing of a list has ended with
stop_execution
or via an external stop signal. The
default value also takes effect together with the
position- and/or speed-dependent laser control (see
set_port_default).
If automatic laser control is activated, then the value
at the 8-bit digital output may automatically get
adjusted (see
page
140). You can log this via
set_trigger/set_trigger4.
When the output value is changed, a LATCH signal is
outputted at the EXTENSION 2 connector as a trigger
signal for synchronization of data transmission
(provided that pin (17) has been correspondingly
configured via the jumper setting, see
9.1.3 2 Bit Digital Output Port
The LASER connector provides a buffered 2-bit digital
output port (DIGITAL OUT1 and DIGITAL OUT2) (see
page
46). Its output values can be set via
set_laser_pin_out
or set_laser_pin_out_list. The
output is in high-impedance mode (tri-state) until an
initial value is assigned to it. In addition, the
command
set_port_default
to define the value to be outputted at the 2-bit digital
output port, as soon as processing of a list has ended
with
stop_execution
or via an external stop signal.
®
RTC
5 PC Interface Board
Rev. 1.9 e
9 Programming Peripheral Interfaces
50).
write_8bit_port
or
page
50).
(Port = 4) can be used

9.1.4 12-Bit Analog Output Ports

The LASER connector provides the two 12-bit analog
output ports, ANALOG OUT1 and ANALOG OUT2 (see
page
47). The ANALOG OUT2 output port is also
available via the MARKING ON THE FLY connector
(see
page
51).
The output values can be separately set via
write_da_x
or write_da_x_list. In addition, the
commands
set_port_default
set_laser_off_default
can be used to define the
values to be outputted at the 12-bit analog output
ports, as soon as processing of a list has ended with
stop_execution
or via an external stop signal. The
default value also takes effect together with the
position- and/or speed-dependent laser control (see
set_port_default). If accordingly preset via corre-
sponding commands, the values at the analog output
ports are also changed via a softstart (see
Mode" on page
135) or in the pixel mode (see
page
192).
If automatic laser control is activated, then the value
at one of the 12-bit analog output ports may auto-
matically get adjusted (see
this via set_trigger/set_trigger4.
(Port = 0 or 1) or
"Softstart
page
140). You can log