Normal
para_mark_abs
List Command
Function
moves the laser focus at marking speed along a 2D vector from the current position to the
specified position (absolute coordinate values) within a two-dimensional image field and,
simultaneously as well as linearly, changes the signal parameter selected via
set_vector_control
Call
para_mark_abs( X, Y, P )
Parameters
X, Y
P
Comments
• If vector-defined laser control has not been previously activated via set_vector_control,
then para_mark_abs will behave like
P will then be ignored.
• If vector-defined laser control is activated, then simultaneously with the laser focus'
motion (Sky writing isn't taken into account here) the signal parameter selected via
set_vector_control
Defined Laser Control", page
• There is no abs mechanism for P. P will, if necessary, be clipped to the maximum allowed
value.
• If para_mark_abs is used along with position- and/or speed-dependent laser control
for the same control parameter, then the current value of P will be used as the basis of
the 100% value for laser control (see
®
®
RTC
4 RTC
5 new command
®
In RTC
4 compatibility mode, the RTC
(the permissible range of values is correspondingly reduced).
The parameter P does not have a RTC
must be used.
References
mark_abs, set_vector_control, para_mark_abs_3d,
®
RTC
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
to the specified value.
absolute coordinates of the mark vector end point in bits as signed 32-bit
values; allowed range: [–8388608 ... 8388607] (out-of-range values will be
edge-clipped). The complete value range [–8388608 ... 8388607] is only
usable as a virtual image field e.g. for (enabled) Processing-on-the-fly
applications. The current coordinates will be clipped to [–524288 ... 524287]
(real image field size) during runtime directly prior to use of the correction
table.
End value of the signal parameter as an unsigned 32-bit value; allowed range:
dependent on the selection made via
identical with
set_vector_control
will be linearly varied from the last valid value to P (see
147).
®
®
4 compatibility mode. The original RTC
set_vector_control
(Value parameter)
mark_abs
(see comments there). The parameter
"Vector-Defined Laser Control", page
5 multiplies the specified coordinate values by 16
para_mark_rel
(Ctrl parameter),
"Vector-
147).
®
5 units
376