Mechanical Installation; Interface X4 (Inputs) - Leibinger JET3 User Manual

Hide thumbs Also See for JET3:
Table of Contents

Advertisement

Group 5
The signal type which should be used as encoder source has to be
set in the software of the JET3 under Settings
Encoder Interface.
You will find a circuit diagram of the interface in the appendix of this
manual!

5.4.3.2 Mechanical installation

If the conditions allow it, the shaft encoder can be also adapted to a production line
with a friction wheel.

5.4.4 Interface X4 (Inputs)

19 inputs for special functions are available whereof the connections of 6 inputs
can be freely selected.
Plug assignment:
Release R1.03e
Transport/Start up
For the mechanical installation of the shaft encoder you have to
pay attention in any case that the encoder is protected against axial
and radial strain during the mounting and the continuous operation.
For this a rubber gaiter or a plastic coupling is used.
Attention – Risks of injury!
The shaft encoder has to be installed or mounted that no risks of
injury can occur!
Pin connection:
Pin
Designation
1
+Reset Counter
2
+Increment Counter
3
+Jobselect 0
4
+Jobselect 2
5
+Jobselect 4
6
+Jobselect 6
7
+Jobselect 8
8
GND Jobselect 0-9
9
+Input 0
10
+Input 2
11
+Input 4
12
+Power ON
13
GND 24V
Basic Settings
Pin
Designation
14
+24V
(1)
15
GND Reset Counter /
Increment Counter
16
+Jobselect 1
17
+Jobselect 3
18
+Jobselect 5
19
+Jobselect 7
20
+Jobselect 9
21
GND Input 0-5
22
+Input 1
23
+Input 3
24
+Input 5
25
GND Power On
LEIBINGER JET3
Page 37

Advertisement

Table of Contents
loading

Table of Contents