Mechanical Installation; Interface X5 (Printgo) - Leibinger JET2 neo Manual

Hide thumbs Also See for JET2 neo:
Table of Contents

Advertisement

Page 46
The signal type which should be used as encoder source has to be
set in the software of the JET2 neo under Main menu
Basic settings
You will find a circuit diagram of the interface in the appendix of this
manual!

5.5.1.2 Mechanical installation

For the mechanical installation of the shaft encoder you have to pay
attention in any case that the encoder is protected against axial and
radial strain during the mounting and the continuous operation. For
this a rubber gaiter or a plastic coupling is used.
If the conditions allow it, the shaft encoder can be also adapted to a production line
with a friction wheel.
Caution – Risks of injury!
The shaft encoder has to be installed or mounted that no risks of
injury can occur!

5.5.2 Interface X5 (PrintGo)

The interface "X5" provides the connection of an external PrintGo-signal. All
common product detectors (e.g. light barrier, product sensor etc.), 24V NPN- as
well as 24V PNP-switching can be connected.
Regarding the software you can select additionally if the positive edge or the
negative edge should be used for the release of the print out.
Note: To inform the JET2 neo when a print text should be printed, you require a so-
called Print-Go signal.
Plug assignment:
Release R1.07 en
Transport/Start up
Interfaces.
Pin connection:
Pin
Designation
1
+24 V
(1)
2
/PrintGo
3
GND
Pin
Designation
4
PrintGo
5
PrintGo_Gate
Group 5
Settings
JET2 neo

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents