15.5.4.3 Connection to the PLC

The following section describes how to connect a Vision Sensor to a PLC. Connection of a Siemens CPU
1516-3 PN/DP with TIA Portal v14 SP1 software is used as an example.
15.5.4.3.1

Determining a permanent IP address and name for the Vision Sensor

The Vision Sensor no longer visible in the PROFINET device list once it is connected to the PLC, since data
transmission via PROFINET is disabled in the Vision Sensor's factory settings.
This section explains how PROFINET is enabled, a persistent IP address is assigned and a device name is
determined for the Vision Sensor.
1.
After connecting the Vision Sensor to the PLC,
the Accessible devices dialogue contained in the
Siemens PLC software package can be used to
monitor whether the connected Vision Sensor is
visible.
It is not, since the factory settings mean that
PROFINET is disabled in the Vision Sensor.
2.
Open the Application Suite.
3.
Connect to the desired Vision Sensor.
4.
Switch to Configuration operating mode.
Open the Device settings  process interface.
5.