Baumer VeriSens ID Series Technical Documentation Manual page 358

Vision sensor
Hide thumbs Also See for VeriSens ID Series:
Table of Contents

Advertisement

3.
Access the properties and enter the correct
name for the Vision Sensor and its stipulated IP
address.
4.
Configure the PROFINET cycle time (4 ms is
advisable) in which data is to be transmitted.
The shortest period supported by Vision
Sensor is 2 ms. Although a period of 4 ms is
recommended.
A shorter period could result in alarms on the
PLC.
Shorter periods reduce the computing power available for feature checking in the Vision Sensor and thus
analysis performance. Longer periods increase the delay during analysis of received data and when
transmitting result data and thus reduce response performance.
The period you choose will therefore be a compromise between these factors.
v2.11.0-B4
358/429
Technical Documentation
VeriSens
Baumer Optronic GmbH
Radeberg, Germany
®

Advertisement